13A Switched Socket Outlets – Side Wire Entry
DAVIS one and two gang 13A Switched Socket Outlets are specially designed to be slim (24mm) with side wire entries to suit underfloor service boxes.
Rating / Standard: 240V, 13A a.c / BS 1363 : Part 2
3 terminals to accommodate: 4 x 2.5mm² cables each or 3 x 4.0mm² cables each
Approved by: JKR & Suruhanjaya Tenaga
Model | Description |
D13/1GS | 1 Gang 13A Switched Socket |
D13/2GS | 2 Gang 13A Switched Socket |
Data & Telephone Outlets
DAVIS modular type RJ45 & RJ11 data outlets are specially designed to suit underfloor service boxes.
Comply with: TIA/EIA-568-B specifications
Come with: IDC connector and shutter
Hole cut-out: 37mm x 22mm
Model | Description |
D-RJ45-CAT6 | CAT 6 RJ45 Data Outlet – TIA/EIA-568-B |
D-RJ11 | 4-Way RJ11 Telephone Socket Outlet |
Service Access Grommets
DAVIS Service Access Grommet provides a convenient and low-cost solution to data, power and voice services for raised access floors. Recommended cut-out hole is 127mm.
Model | Description |
SFGR-D127G | 5″ Service Access Grommet w/o Box |
SFGR-D127G/S | 5″ Service Access Grommet c/w 1 Gang 13A Switched Socket Outlet |
SFGR-D127G/R | 5″ Service Access Grommet c/w 2 nos. RJ45 / RJ11 Knock out Hole |
Underfloor Box Extension Screw Terminals
Model | Description* |
EXT 70 + EXT 65 | 120 – 160mm |
EXT 90 | 96 – 118mm |
EXT 65 | 71 – 93mm |
EXT 40 | STANDARD ( 50 – 68mm ) |
* screed depth for 25mm trunking entry
Floor Pedestal Boxes
DAVIS Pedestal Boxes are available in 3 designs : 1 gang, 2 x 1 gang and 2 gang for mounting onto Underfloor or Flushfloor Trunkings. These are constructed from pre-galvanized steel sheets with epoxy finish. The socket outlet fixing is in accordance with BS 4662.
Power Distribution Tower
Model | Description |
D95/PDT/610/3 | 1 Gang Power Socket Tower (100W x 50D x 610H) 3 Outlets |
D95/PDT/610/6 | 1 Gang Power Socket Tower (100W x 50D x 610H) 6 Outlets |
Metalclad Distribution Board
DB Series: Suitable to fit Isolator, Switchfuse or MCB as main switch
DBM Series: Suitable to fit MCCB as main switch
No. of Row | H (mm) | W (mm) | D (mm) | DB Series | DBM Series | ||
Model | No. of way | Model | No. of way | ||||
1 | 205 | 335 | 85 | DB115 | 15 | – | – |
1 | 205 | 405 | 85 | DB118 | 18 | – | – |
1 | 205 | 475 | 85 | DB122 | 22 | – | – |
2 | 335 | 405 | 110 | DB216 | 32 | DBM216 | 22 |
3 | 565 | 405 | 110 | DB316 | 48 | DBM316 | 43 |
4 | 750 | 405 | 110 | DB416 | 64 | DBM416 | 59 |
5 | 885 | 405 | 110 | DB516 | 80 | DBM516 | 75 |